Description
DC outputs
• Floating outputs on 4 mm safety sockets.
• Three switchable outputs : 6 V, 12 V or 24 V.
• Accuracy : ± 1%
• Regulation : < 40 mV at 6 and 12 V outputs for a load variation from 0 to 100%.
< 20 mV at 24 V output for a load variation from 0 to 100%.
• Ripple : < 5 mV peak to peak or 1,8 mV rms.
• Internal resistance : < 4 mΩ.
Current
• Max I : 10 A at 6 or 12 V output.
5 A at 24 V output.
Protection
• Short circuit protection by fold-back current limit, allowing continuous short
circuit without overheating.
AC outputs
• Floating outputs on 4 mm safety sockets.
• Three outputs with common point.
• Voltages : 6 Volts, 12 Volts and 24 Volts ± 10%.
• No-load voltage 5% maximum.
Current
• Max I : 10 A at 6 and 12 V outputs.
5 A at 24 V output.
Protection
• Secondary overcurrent protection by auto-reset thermal circuit-breakers.
Precautions
• The AC and DC circuits can be used simultaneously but with a max power of 120 W
Other specifications
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, overvoltage category II, pollution degree 2.
• EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B.
• Transformer primary overcurrent protection, by fuse.
• Input voltage : 230 V ±10%, 50/60 Hz.
• Mains input : Socket C14 with C13 removable cable (2 poles + earth).
• Power consumption : 250 VA max.
• Dielectric strength : 3700 V from input to output, 2200 V from input to chassis.
• Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish