Description
Voltage
• Floating outputs : on 4 mm safety terminals in the front-panel, and on screw terminal block for 2.5mm² on the rear-panel.
• Automatic constant voltage operation.
• Adjustable from 0 to 32.00 Volts (0 to ±10 mV) ; resolution : 10 mV.
• Setting accuracy : 0,03% + 10 mV.
• Regulation : < 50 mV for a load change from 10 to 90%.
< 1 mV for a ±10% line change.
•Ripple : < 1 mV rms including :
< 3 mV peak to peak of noise (BP 20 MHz)
< 15 mV peak to peak of switching spikes
• Internal resistance : < 4 mΩ.
• Display : 4 digits on graphic LCD.
• Accuracy measurement : 0,03% + 10 mV.
Current
• Automatic constant current operation.
• Adjustable from 0 to 20.00 Amps ; resolution : 10 mA.
• Setting accuracy : 0,05% + 10 mA.
• Regulation : < 10 mA for a load charge from 10 to 90%.
< 1 mA for a ±10% line charge.
• Ondulation : < 6 mA peak to peak or 2 mA rms.
• Display : 4 digits on graphic LCD.
• Accuracy measurement : 0,05% + 10 mA.
Protections
• Against short-circuits, by current regulation.
• Against overtemperature by fan and thermal circuit-breaker.
• Against overcurrent on main input, by internal fuses.
Various and functions
• Dispaly : Graphic LCD 128 x 64 pixels with white backlight.
Visualization of all parameters CV (Constant Voltage) mode or CC (Constant Current)
• Memories : 16 including 15 configurable
• OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi.
• Functions : 6 available on U or I(Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot).
Time adjustement from 10 ms to 60 mn.
• Remote sensing : automatic function on the front side output.
4 wires mode on the back-side’s terminal blocks.
Correction of the voltage drop in the wires : 2 V
• Standby : output, enable / disabled and standby of the power supply.
Interfaces
All the interfaces are insulated of the output (150 VDC max).
• USB, RS232 and RS485 as a standard.
•*ETHERNET option : RS232 / RS485 / RS422 adapter kit to ETHERNET.
• LabVIEW™’s drivers as a standard.
• Controller 0 – 10 V : for U and I by direct input 0 – 10 V
or potentiometer or adjustable resistance 10 kW.
In the back side on disconnect scribe terminal blocks.
Other specifications
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, CAT II.
• CEM : Complies with EN 61326-1 and EN 55011.
• Input voltage : 220 – 240 Volts ±10%, 50/60Hz.
• Mains input : Socket CE14 with C13, 2 poles + earth cable removable
• Power consumption : 770 W maxi.
• Efficiency : > 84% of the maxi powerful.
• Operating temperature : +5 to +40 °C.
• Coefficient of temperature /°C : 0.01% for the voltage ; 0.05% for the current.
• Voltage on the earth : 150 VDC Max.
• Presentation : Front-panel with sensitiv keypad, rear-panel with
handle and cord storage area, metallic case with epoxy finish