PRATICAL : Digital display of voltage and current.
EASY : Automatic mode select button : separate, tracking and series.
PRECISE : Fine voltage adjustment.
QUIET : Silent temperature-controlled fan cooling

Download documentationDownload the quick user manual

420,00  HT

Double regulated bench power supply : 2×0-30V 1x±0-30V ; 1×0-60V ; 180W

EAN: 3760244880031 Ref. : ALR3003D Categories , Tag

PRATICAL : Digital display of voltage and current.
EASY : Automatic mode select button : separate, tracking and series.
PRECISE : Fine voltage adjustment.
QUIET : Silent temperature-controlled fan cooling

Download documentationDownload the quick user manual

420,00  HT

Description

CHANNELS                MASTER AND SLAVE
                                          Independant     Tracking              Series
Output voltage              2 x 0 – 30 V      ± 0 – 30 V              0 – 60 V

Output current             2 x 0 – 3 A          ± 0 – 3 A                0 – 3 A

Power Supplies A and B (master and slave)
• The “Tracking/Series” mode internally connects the – terminals of the
master and + terminals of the slave (mid point).
All adjustments are made from the slave power supply.
• The parallel mode* (external connection) provides up to 6 amperes.
• Indicators : green LED for voltage regulation red LED for current regulation.
• Display of voltage and current on 14 mm 3 digit red LED displays.

Protection
• Short circuit protection, by current regulation.
• Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay.
• Transformer primary overcurrent protection, by fuse.

Other specifications
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, overvoltage category II, pollution degree 2.
Toroidal isolation transformer, class II, complies with EN 61558-2-4.
• EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B.
• Input voltage : 230V ±10%, 50 / 60 Hz.
• Mains input : EEC socket with 2 poles + earth cable
• Power consumption : 400 VA.
• Dielectric strength : 2300V between input, output and chassis.
• Outputs : safety sockets and safety inverted earth socket.
• Presentation : screen-printed polycarbonate front panel, meta case, epoxy finish

Additional information

Nombre de voie

2 channels

Puissance

180 WATTS

Volts

0 – 30 V, 0 – 60 V, 0 V – ±15 V

Ampères

0 – 3 A, 0 – 6 A

Regulations

• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, overvoltage category II, pollution degree 2.
Toroidal isolation transformer, class II, complies with EN 61558-2-4.
• EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B.