EASY : Direct digital display of voltage and current, even in the series or parallel mode.
SURE : Automatic disconnection each time the master and slave channel configuration is changed.
COMPLETE : Third channel with fixed or variable position and voltage or current display.
EFFECTIVE : Idc adjustment independent of load.
QUIET : Silent temperature-controlled fan cooling

Download documentationDownload the quick user manual

525,00  HT

Triple outputs regulated bench power supply : 2x 0-30V / 0-3A ; + 2-15V ; 200W

EASY : Direct digital display of voltage and current, even in the series or parallel mode.
SURE : Automatic disconnection each time the master and slave channel configuration is changed.
COMPLETE : Third channel with fixed or variable position and voltage or current display.
EFFECTIVE : Idc adjustment independent of load.
QUIET : Silent temperature-controlled fan cooling

Download documentationDownload the quick user manual

525,00  HT

Description

CHANNELS MASTER AND SLAVE  + AUXILARY
                           Independent   Tracking         Series         Parallel      Variable Auxiliary
Output volt.     2x 0 – 30 V       ± 0 – 30 V      0 – 60 V     0 – 30 V       2 – 5,5 V 5,5 – 15 V

Output cur.      2x 0 – 3 A         ± 0 – 3 A          0 – 3 A       0 – 6 A         3 A               1 A

Power supplies A and B (master and slave)
• The Standby mode disconnects the output terminals. It is automatic upon a change of mode.
• The Idc push-button shorts the output in the standby mode. It is used for setting Imax.
• Indicators : green LED for voltage regulation red LED for current regulation.
• Display : automatic display switching depending on selected configuration.

AUXILIARY power supply
• The Display button switches the display between voltage and current.
• The voltage is continuously adjustable from 2 to 15 V.
The max current goes from 3 A to 1 A after 5,5 V.

Protection
• Short circuit protection, by current regulation.
• Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay.
• Transformer primary overcurrent protection, by fuse.

Other specifications
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, overvoltage category II, pollution degree 2.
Toroidal transformer, class II, complies with EN 61558-2-4.
• EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B.
• Input voltage : 230 V ±10%, 50/60 Hz.
• Mains input : Socket C14 with C13 removable cable (2 poles + earth).
• Power consumption : 410 VA.
• Dielectric strength : 2300 V between input, output and chassis.
• Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal.
• Presentation : screen-printed polycarbonate front panel, metalcase, epoxy finish.

Additional information

Nombre de voie

3 channels

Puissance

200 WATTS

Volts

0 – 30 V, 0 – 60 V, 0 V – ±0 – 30V, 1 – 15 V, 5,5 – 15 V

Ampères

0 – 3 A, 0 – 6 A, 1 A, 3 A

Regulation

• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, overvoltage category II, pollution degree 2.
Toroidal transformer, class II, complies with EN 61558-2-4.
• EMC : Complies with EN 61326-1, performance criteria B, and EN 55011, ISM Group I, Class B.