EAN: 3760244880925 SKU ALR3203 Categories , Tags ,

VISUAL : Large graphic display
SOFT-TOUCH : Sensitiv keypad
CONNECTED : USB isolated, LabVIEW™ drivers and executable provided
FUNCTIONS : Arbitrary, square, positive and negative ramp, rise or fall time
ELEGANT : New design and feathery
SPACE-SAVING : vertical case, COMPACT DESIGN
PRACTICAL : Lightweight with built-in handle and cord storage area.
QUIET : Without fan.
LOCKING : configuration & stand-by

Download documentationDownload the quick user manualDownload the detailed user manual

325,00  HT

Programmable bench power supply : 0-32V ; 0-6A ; 96W

EAN: 3760244880925 Ref. : ALR3203 Categories , Tags ,

VISUAL : Large graphic display
SOFT-TOUCH : Sensitiv keypad
CONNECTED : USB isolated, LabVIEW™ drivers and executable provided
FUNCTIONS : Arbitrary, square, positive and negative ramp, rise or fall time
ELEGANT : New design and feathery
SPACE-SAVING : vertical case, COMPACT DESIGN
PRACTICAL : Lightweight with built-in handle and cord storage area.
QUIET : Without fan.
LOCKING : configuration & stand-by

Download documentationDownload the quick user manualDownload the detailed user manual

325,00  HT

Description

Voltage
• Floating outputs : on 4 mm safety terminals.
• Automatic constant voltage operation.
• Adjustable from 0 to 32,00 Volts (0 to ±10 mV) ; resolution : 10 mV.
• Setting accuracy : 0,03% + 10 mV.
• Regulation : < 20 mV for a load change from 10 to 90%.
< 1 mV for a ±10% line change.
•Ripple : < 1,5 mV rms including :
< 5 mV peak to peak of noise (BP 20 MHz)
< 10 mV peak to peak of switching spikes
• Internal resistance : < 4 mΩ.
• Display : 4 digits on graphic LCD.
• Accuracy measurement : 0,06% + 10 mV.

Current
• Automatic constant current operation.
• Adjustable from 0 to 6,000 Amps ; resolution : 2 mA.
• Setting accuracy : 0,03% + 2 mA.
• Pmax : 96 W ; Imax : 6 A from 0 to 16V then decreasing to 3 A ; 32 V
• Regulation : < 1 mA for a load charge from 10 to 90%.
< 1 mA for a ±10% line charge.
• Ondulation : < 1 mA peak to peak or 0.4 mA rms.
• Display : 4 digits on graphic LCD.
• Accuracy measurement : 0,06% + 2 mA.

Protections
• Against short-circuits, by current regulation.
• Against overtemperature by thermal circuit-breaker.
• Against overcurrent on main input, by internal fuses.

Various and functions
• Dispaly : Graphic LCD 128 x 64 pixels with white backlight.
Visualization of all parameters (CV, CC, RMT, …)
• Memories : 16 including 15 configurable.
• OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi.
• Functions : 6 available on U or I
(Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot).
Time adjustement from 100 ms to 50 mn.
• Standby : output, enable / disabled and standby of the power supply.

Interfaces
• USB, as a standard, insulated of the output (150 VDC max).
• LabVIEW™’s drivers as a standard

Other specifications
• Safety : Class I, enhanced safety between mains input and outputs
Complies with EN 61010-1, CAT II. Output Safety Extra Low Voltage (SELV)
• CEM : Complies with EN 61326-1 and EN 55011.
• Input voltage : 220 – 240 Volts ±10%, 50/60Hz.
• Mains input : Socket CE14 with C13, 2 poles + earth cable removable
• Power consumption : 126 W maxi.
• Efficiency : > 78% of the maxi powerful.
• Operating temperature : +5 to +40 °C.
• Coefficient of temperature /°C : 0.01% for the voltage ; 0,05% for the current.
• Voltage on the earth : 150 VDC Max.
• Presentation : Front-panel with sensitiv keypad, rear-panel with handle and cord storage area, metallic case with epoxy finish

Additional information

Puissance

96 WATTS

Nombre de voie

1 channel

Volts

0 – 32 V

Ampères

0 – 6 A

Regulations

• Safety : Class I, enhanced safety between mains input and outputs
Complies with EN 61010-1, CAT II. Output Safety Extra Low Voltage (SELV)
• CEM : Complies with EN 61326-1 and EN 55011.