Channels 1 and 2MASTER AND SLAVE Independent TrackingSeriesParallel Output voltage 2 x 0 – 32 V± 0 – 32 V0 – 64 V0 – 32 V Output current 2 x 0 – 6 A± 0 – 6 A0 – 6 A0 – 12 A
Protections
• Against short-circuits, by current regulation
• Against overtemperature by fan and thermal circuit-breaker.
• Against overcurrent on main input, by internal fuses.
Various and functions
• Dispaly : Graphic LCD 128 x 64 pixels with white backlight.
Visualization of all parameters (CV, CC, RMT, etc….)
• Memory : 16, including 15 configurable.
• OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi.
• Functions : 6 available on U or I (Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot).
Time adjustement from 10 ms to 60 mn.
• Remote sensing : 4 wires mode on the back-side’s terminal blocks.
Correction of the voltage drop in the wires : 2 V
• Standby : output, enable / disabled and standby of the power supply.
Interfaces
All the interfaces are insulated of the output (150VDC max).
• USB and RS485 are standard.
• *ETHERNET WIFI option : RS232 / RS485 / RS422 adapter kit to ETHERNET or RS232 / RS485 adapter kit to WIFI & ETHERNET.
• LabVIEW™’s drivers as a standard.
• 0 – 10 V command : for U & I for CH1 or U for CH1 & CH2 by direct input
0-10 V or 10 kW adjustable potentiometer/resistance.
In the back side on disconnect scribe terminal blocks.
Other specifications
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, CAT II.
• CEM : Complies with EN 61326-1 and EN 55011.
• Input voltage : 220-240 Volts ±10%, 50/60Hz.
• Mains input : socket C14 with C13 2 poles + earth cable removable
• Power consumption : 490 W maxi.
• Efficiency : > 78% of the maxi powerful.
• Operating temperature : +5 to +40 °C.
• Coefficient of temperature /°C : 0.01% for the voltage and the current.
• Voltage on the earth : 150 VDC Max.
• Presentation : Front-panel with sensitiv keypad, rear-panel with
handle and cord storage area, metallic case with epoxy finish.
Additional information
Nombre de voie
2 channels
Puissance
640 WATTS
Volts
0 – 32 V, 0 – 64 V
Ampères
0 – 12 A, 0 – 6 A
Connectique
RS232, USB or LAN
Regulations
• Safety : Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, CAT II.
• CEM : Complies with EN 61326-1 and EN 55011.