EAN: 3760244880291 SKU ALE2401 Categories , Tag

PRECISE : Output ripple < 3 mV rms.
– Remote sensing to overcome voltage drop in the power lines.
PRACTICAL : Output voltage adjustable from 20 to 30 V.
– Spring terminal block.
PROTECTED : Short circuit protection.
EASY : Direct DIN rail or panel mounting.

Download documentationDownload the user manual

53,00  HT

DIN RAIL regulated switching power supply : 24V (Adj. 20 to 30V) 30W

EAN: 3760244880291 Ref. : ALE2401 Categories , Tag

PRECISE : Output ripple < 3 mV rms.
– Remote sensing to overcome voltage drop in the power lines.
PRACTICAL : Output voltage adjustable from 20 to 30 V.
– Spring terminal block.
PROTECTED : Short circuit protection.
EASY : Direct DIN rail or panel mounting.

Download documentationDownload the user manual

53,00  HT

Description

Voltage
• Floating outputs on spring terminal block for 2,5 mm² (AWG12) wires
• Output voltage : adujustable from. 20 to 30 V.
• Regulation : < 20 mV for a load variation from. 0 to 100%
5 mV for a line variation from -10 to +10%.
• Ripple : < 3 mV rms including :
3 mV peak to peak of the signal at 65 kHz
< 4 mV peak to peak of the signal at 100 Hz
< 20 mV peak to peak of switching spikes
• Hold-up time : 50 ms at full load (230 V line input)
• Indicator : green power-on LED indicator

Current
• Max I : 1,5 A at 20 V
1,25 A at 24 V
1 A at 30 V

Power
• Max output power : 30 W

Protections
• Against short-circuits by circuit breaker with automatic reset
• Against transients on the primary circuit by varistor
• Against overcurrent on primary circuit by fuse

Remote sensing
• Correction of the voltage drop in the wires (4 wires method)
• Input on disconnect scribe terminal blocks for 2,5 mm2 wires (AWG12)
• Correction : Max 3 V (1,5 V per wire)
• Ripple : <30 mV for a load variation from 0 to max

Other specifications
• Safety : Class II, Safety Extra Low Voltage (SELV), complies with EN 61010-1, EN 61010-2-201 and EN 62368-1.
• EMC : Complies with EN 61000-6-2 and EN 61000-6-4.
• Overvoltage Category : II ; Pollution Degree : 2.
• Installation altitude : < 2000 m.
• Protection level : IP30
• Operating temperature : from -25 °C to +70 °C
Derating : 1 W/°C from +55 °C
• Input voltage : 220-240 VAC (190 to 264 VAC), 50-60 Hz
• Mains input : disconnect scribe terminal blocks for 2,5 mm² wires (AWG12)
• Power consumption : max 34,5 W
• Dielectric strength : 3000 VAC from Input to output
• Presentation : polycarbonate modular case (3 modules) screenprinted
• Dimension : 54 x 95 x 58 mm (lxhxp)
• Mounting : Clipspackage integrated in modular case for DIN rail profile 35×7,5 mm or 35×15 mm
removable wall mounting integrated case to the 4 mm screws

Additional information

Nombre de voie

1 channel

Puissance

30 WATTS

Volts

24 V, 24 V (Adj 20 to 30 V), 27,2 V, PRIM. 230 V

Ampères

1,25 A

Regulations

• Safety : Class II, Safety Extra Low Voltage (SELV), complies with EN 61010-1, EN 61010-2-201 and EN 62368-1.
• EMC : Complies with EN 61000-6-2 and EN 61000-6-4.
• Overvoltage Category : II ; Pollution Degree : 2.
• Installation altitude : < 2000 m.
• Protection level : IP30